INVERTER DEYE 12K THREE PHASE AU-3P12K1G-LE-EU

  • 100% unbalanced output, each phase; Max. output up to 50% rated power
  • AC couple to retrofifit existing solar system
  • Max. 10 pcs parallel for on-grid and off-grid
    operation; Support multiple batteries parallel
  • Max. charging/discharging current of 240A
  • Support storing energy from diesel generator
  • 48V low voltage battery, transformer isolation design
  • 6 time periods for battery charging/discharging
Category: Tag:

SUN-12K-SG05LP1-EU Specifications


Battery Input Data:

  • Battery Type: Lead-acid or Lithium-ion
  • Battery Voltage Range (V): 40-60
  • Max Charging Current (A): 210
  • Max Discharging Current (A): 210
  • Charging Strategy for Li-ion Battery: Self-adaption to BMS
  • Number of Battery Inputs: 1

PV String Input Data:

  • Max PV Access Power (W): 20,000
  • Max PV Input Power (W): 16,000
  • Max PV Input Voltage (V): 500
  • Start-up Voltage (V): 125
  • MPPT Voltage Range (V): 150-425
  • Rated PV Input Voltage (V): 370
  • Max Input Short-Circuit Current (A): 34+34
  • Max Operating PV Input Current (A): 26+26
  • No. of MPP Trackers / No. of Strings Per MPP Tracker: 2/2+2

AC Input/Output Data:

  • Rated AC Input/Output Active Power (W): 12,000
  • Max AC Input/Output Apparent Power (VA): 13,200
  • Peak Power (Off-Grid) (W): 2× Rated Power for 10s
  • Rated AC Input/Output Current (A): 54.5 / 52.2
  • Max AC Input/Output Current (A): 60 / 57.4
  • Max Continuous AC Passthrough (Grid to Load) (A): 50
  • Rated Input/Output Voltage / Range (V): 220V/230V (0.85Un-1.1Un)
  • Grid Connection Form: L+N+PE
  • Rated Input/Output Grid Frequency / Range: 50Hz / 45Hz-55Hz or 60Hz / 55Hz-65Hz
  • Power Factor Adjustment Range: 0.8 Leading – 0.8 Lagging
  • Total Current Harmonic Distortion (THDi): <3% (of nominal power)
  • DC Injection Current: <0.5%In

Efficiency:

  • Max Efficiency: 97.6%
  • Euro Efficiency: 96.5%
  • MPPT Efficiency: >99%

Equipment Protection:

  • Integrated protection includes:
    • DC Polarity Reverse Connection Protection
    • AC Output Overcurrent Protection
    • Thermal Protection
    • AC Output Overvoltage Protection
    • AC Output Short Circuit Protection
    • DC Component Monitoring
    • Overvoltage Load Drop Protection
    • Ground Fault Current Monitoring
    • Arc Fault Circuit Interrupter (optional)
    • Power Network Monitoring
    • Island Protection Monitoring
    • Earth Fault Detection
    • DC Input Switch
    • DC Terminal Insulation Impedance Monitoring
    • Residual Current (RCD) Detection
    • Surge Protection Level: TYPE II (DC), TYPE II (AC)

Interface:

  • Communication Interface: RS485 / RS232 / CAN
  • Monitor Mode: GPRS / WIFI / Bluetooth / 4G / LAN (optional)

General Data:

  • Operating Temperature Range: -40°C to +60°C (Derating above 45°C)
  • Permissible Ambient Humidity: 0~100%
  • Permissible Altitude: 2000m
  • Noise: <30 dB(A)
  • Ingress Protection (IP) Rating: IP65
  • Inverter Topology: Non-Isolated
  • Overvoltage Category: OVC II (DC), OVC III (AC)
  • Cabinet Size (W × H × D) [mm]: 330 × 580 × 232 (Excluding Connectors and Brackets)
  • Weight [kg]: 24.9
  • Warranty: 5 Years / 10 Years (depends on installation site; refer to warranty policy)
  • Type of Cooling: Intelligent Air Cooling

Grid Regulation Standards:

  • IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105

Safety and EMC Standards:

  • IEC/EN 61000-6-1/2/3/4
  • IEC/EN 62109-1
  • IEC/EN 62109-2

Reviews

There are no reviews yet.

Be the first to review “INVERTER DEYE 12K THREE PHASE AU-3P12K1G-LE-EU”