Battery Input Data:
- Battery Type: Lead-acid or Lithium-ion
- Battery Voltage Range: 40-60V
- Max Charging Current: 120A
- Max Discharging Current: 120A
- Charging Strategy for Li-ion Battery: Self-adaption to BMS
- Number of Battery Inputs: 1
PV String Input Data:
- Max PV Access Power: 10,000W
- Max PV Input Power: 6,500W
- Max PV Input Voltage: 500V
- Start-up Voltage: 125V
- MPPT Voltage Range: 150-425V
- Rated PV Input Voltage: 370V
- Max Input Short-Circuit Current: 17A + 17A
- Max Operating PV Input Current: 13A + 13A
- Number of MPP Trackers / Number of Strings per MPP Tracker: 2 / 1+1
AC Input/Output Data:
- Rated AC Input/Output Active Power: 5,000W
- Max AC Input/Output Apparent Power: 5,500VA
- Peak Power (Off-grid): 10,000W (2x rated power, 10 seconds)
- Rated AC Input/Output Current: 22.7A / 21.7A
- Max AC Input/Output Current: 25A / 23.9A
- Max Continuous AC Passthrough (Grid to Load): 40A
- Rated Input/Output Voltage / Range: 220V/230V (0.85 Un – 1.1 Un)
- Grid Connection Form: L+N+PE
- Rated Input/Output Grid Frequency / Range: 50Hz / 45Hz-55Hz, 60Hz / 55Hz-65Hz
- Power Factor Adjustment Range: 0.8 leading – 0.8 lagging
- Total Current Harmonic Distortion (THDi): <3% (of nominal power)
- DC Injection Current: <0.5%ln
Efficiency:
- Max Efficiency: 97.6%
- Euro Efficiency: 96.5%
- MPPT Efficiency: >99%
Equipment Protection:
- Integrated Protection:
- DC Polarity Reverse Connection Protection
- AC Output Overcurrent Protection
- Thermal Protection
- AC Output Overvoltage Protection
- AC Output Short Circuit Protection
- DC Component Monitoring
- Overvoltage Load Drop Protection
- Ground Fault Current Monitoring
- Arc Fault Circuit Interrupter (optional)
- Power Network Monitoring
- Island Protection Monitoring
- Earth Fault Detection
- DC Input Switch
- DC Terminal Insulation Impedance Monitoring
- Residual Current (RCD) Detection
- Surge Protection Level: TYPE II (DC), TYPE II (AC)
Interface:
- Communication Interface: RS485 / RS232 / CAN
- Monitoring Mode: GPRS / WIFI / Bluetooth / 4G / LAN (optional)
General Data:
- Operating Temperature Range: -40 to +60°C (derating above 45°C)
- Permissible Ambient Humidity: 0~100%
- Permissible Altitude: 2,000m
- Noise Level: <30 dB(A)
- Ingress Protection (IP) Rating: IP 65
- Inverter Topology: Non-Isolated
- Over Voltage Category: OVC II (DC), OVC III (AC)
- Cabinet Size (W x H x D): 330 x 580 x 232 mm (excluding connectors and brackets)
- Weight: 25 kg
Cooling:
- Type of Cooling: Intelligent air cooling
Grid Regulation:
- IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105
Safety EMC/Standard:
- IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2